Aqua Environment Co. Inc.

Home | Parts by Function / Model | Application Notes


Parts List by Function
(Click on O&M Sheet or Technical Bulletin for details.)
Valves are rated to 6000 PSI inlet pressure except for the 1575 Reducing Regulator (7000PSI Inlet) and the 1607 Relief Valve (7500PSI Inlet).

Function Type Model Operation &
Maintenance
Sheet
Technical Bulletin
Adapter SCBA Fill, 4500 PSI 708 732 730
  SCBA Fill, 4500 or 2215 PSI 835 732 730
Filter Tee Type 1397 1398 1399
Indicator Moisture & CO 585 600 588
  Humidity Element 592-5 600-1 none
  CO/Humidity Element 592-6 600-2 none
Flow Limiting Device Flow Fuse 443 984 650
  Restrictor 796 984 650
Back Pressure Regulator Dual Outlet 211 550 564
  High Flow 635 646 645
  For Small Compressors 1310 1308 1309
Reducing Regulator,
Hand Load
0-400 PSI Outlet 415-400 753-400 587
Reducing Regulator,
Hand Load
0-1500 PSI Outlet 415-1500 753-1500 587
Reducing Regulator,
Hand Load
400-6000 PSI Outlet, Series 415 753 587
  Repair Kit 415 839 none
  0-150 PSI Outlet 873-150 875-150 874
  400 PSI Outlet 873-400 875-400 874
  1500 PSI Outlet 873-1500 875-1500 874
  5000 PSI Outlet 873-5000 875-5000 874
  400 PSI Outlet, Heated 873H-400 875H-400 none
  1500 PSI Outlet, Heated 873H-1500 875H-1500 none
  5000 PSI Outlet, Heated 873H-5000 875H-5000 none
  0-250 PSI, Single Inlet & Outlet 969 980 981
  5000 PSI Outlet, Single Inlet & Outlet 1120 1121 1122
  20-1000 PSI Outlet, Small, In-line 1247 1248 1250
  6000 PSI Outlet, High Accuracy 1372 1373 1419
  7000 PSI Inlet, 700-6000 PSI Outlet 1575 1576 1577
Reducing Regulator,
Dome Load
6000 PSI Outlet 873-D 875-dome 874
  6000 PSI Outlet, Non-Vented 1026 1030 1031
  4000 PSI Outlet, With Bias 1053 1078 1080
  6000 PSI Outlet, Non-Vented, High Flow 1092 1101 1031
  Amplifying (Outlet pressure = 44 * Dome pressure) 1262 1263 1265
  Amplifying (Outlet pressure = 15 * Dome pressure) 1262-1500 1263-1500 1265
Switch Pressure 853 854 856
  Pressure, Temperature Compensating 853-1 854 856
Bleed Valve In-line 712 1000 731a
  Separator drain or Bleed 1584 1587 731a
Check Valve High flow, 1/2" NPT 684 690 598a
  1/4" NPT 955 957 598a
Relief Valve 0-6000 PSI Inlet 504 933 651
  0-6500 PSI Inlet 504H 933 651
  0-7500 PSI Inlet 1607 1608 1610
Sequence Valve For Automatic Cascading 1018 1024 1025
  High Flow 1085 1100 1025
Hand Op Valve Toggle, 2 Way 816 819 818
  Toggle, 2 Way, High Flow 1091 1087 1089
  Toggle, 3 Way 816V 819 none
Air Op Valve 2 Way 816-1 819-1 818
  2 Way, Lower Control Pressure 816-3 819-3 none
  3 Way, Lower Control Pressure 816-3V 819-3V none
  2 Way, High Flow 1094 1102 1089
Unloader Valve 70 PSI Minimum Control Pressure 907 908 881

Warranty Policy

If you can't read the O&M's, get Adobe Acrobat Reader.
If you can't read the Tech Bulletins, get Microsoft Word Viewer.